Optimasi Kinerja Steam Turbine Generator 4 Pada Power Plant 2 Utilities dengan Menaikkan Inlet Steam Flow (Studi Kasus PT. X)

Authors

  • I Ketut Warsa Program Studi Pengolahan Minyak dan Gas, Sekolah Tinggi Teknologi Migas
  • Sahrul Rhomadan Program Studi Pengolahan Minyak dan Gas, Sekolah Tinggi Teknologi Migas
  • Eka Megawati Program Studi Pengolahan Minyak dan Gas, Sekolah Tinggi Teknologi Migas

DOI:

https://doi.org/10.32493/jitk.v9i1.42520

Keywords:

Optimization, Steam Flow, Generator Turbines, Power Generation, Electrical Energy

Abstract

Electrical energy has an important role for home needs such as washing machines and irons, as well as for the industrial sector such as power plants and other infrastructure. To create electrical energy, a system is needed which is known as a power plant.. At PT. X electrical energy is produced from the Power Plant which contains supporting equipment, one of which is the Steam Turbine Generator. A Steam Turbine generator is a machine that produces electrical energy from the use of hot steam converted into mechanical energy which is connected by the turbine shaft to the generator. In the refinery operation process, it is very important to know the optimal performance of the Steam Turbine Generator. The research aims to obtain the optimization value of Steam Flow Steam Turbine Generator 4 at Power Plant 2 and to analyze the resulting performance optimization comparison. Optimizing the performance of Steam Turbine Generator 4 Power Plant 2 was carried out by increasing the Steam Flow by 5 Ton/day from 23.80 Ton/day to 63.80 Ton/day. Optimal performance on Steam Turbine Generator 4 Power Plant 2 is obtained at a Steam Flow of 63.80 Tons/day with an electrical power of 12.6 MW which will produce an efficiency value of 80.76%.

References

Apriandi, R., & Mursadin, A. (2016). Analisis Kinerja Turbin Uap Berdasarkan Performance Test PLTU PT. Indocement P-12 TARJUN. Scientific Journal of Mechanical Engineering Kinematika, 1(1). https://doi.org/10.20527/sjmekinematika.v1i1.26

Arrazi, M., Zamzami, & Maimun. (2023). Analisis Efisiensi Turbin Uap Sebagai Penggerak Generator Pabrik Minyak Kelapa Sawit PT. Syaukath Sejahtera (GANDAPURA). Jurnal Tektro, 7(1).

Fadila, A., & Permana, D. S. (2024). Analisis Kinerja Turbin Uap Sebelum Dan Sesudah Overhaul PLTU X. Jurnal Teknik Mesin, 13(1), 35–41.

Komarudin, K., Saputro, A., & Wahyuningsih, E. (2020). Analisis Kenaikan Plant Heat Rate Pltu Sebelum Perbaikan Berkala Terhadap Kondisi Testing Komisioning (Studi Kasus : PLTU XX). Bina Teknika, 16(1), 25. https://doi.org/10.54378/bt.v16i1.1740

Lintang, G. G. (2016). Analisis Pengaruh Perubahan Beban Generator terhadap Efisiensi Kerja Pembangkit Listrik Tenaga Uap (Aplikasi Pada PLTU Pangkalan Susu 2 x 220 MW). Universitas Sumatera Utara.

Santoso, H. (2018). Optimalisasi untuk Menghasilkan Efisiensi Ideal Turbin Uap Pembangkit Listrik TenagaBiomassa Kapasitas 20 MW. STRING (Satuan Tulisan Riset dan Inovasi Teknologi), 3(2). https://doi.org/10.30998/string.v3i2.3044

Saputro, E. (2021). Analisis Efisiensi Turbin Uap Unit 1 di PT. PJB Ubjom Pltu Pulang Pisau Kalimantan Tengah. JTAM ROTARY, 3(1). https://doi.org/10.20527/jtam_rotary.v3i1.3278

Setiawan, F., Melkias, A., & Slameto. (2022). Analisis Kinerja Turbin Uap Unit 1 Di Cirebon Power. Jurnal Teknik Energi, 11(2), 7–11. https://doi.org/10.35313/energi.v11i2.3517

Suriaman, I., & Suprayitno, A. (2022). Analisis Pengaruh Laju Uap Terhadap Efisiensi Turbin Uap Condensing Pada Pltu Pt. Xxx. Jurnal Teknologika, 12(2).

Zakaria, T., & Suryaman, T. (2020). Analisa Kerusakan Kondensor Unit 1- 4 PLTU - XYZ Banten (an Engineering Report Case Study). Jurnal Intent: Jurnal Industri dan Teknologi Terpadu, 3(2). https://doi.org/10.47080/intent.v3i2.957

Zulkarnaini, Z. (2019). Analisa Proteksi Arus Lebih Pada Generator PLTU Teluk Sirih. Jurnal Teknik Elektro ITP, 8(1), 28–34. https://doi.org/10.21063/jte.2019.3133806

Downloads

Published

2025-01-30

How to Cite

I Ketut Warsa, Sahrul Rhomadan, & Megawati, E. (2025). Optimasi Kinerja Steam Turbine Generator 4 Pada Power Plant 2 Utilities dengan Menaikkan Inlet Steam Flow (Studi Kasus PT. X). Jurnal Ilmiah Teknik Kimia, 9(1), 8–13. https://doi.org/10.32493/jitk.v9i1.42520